FlowJam S –
Material flow monitoring
Microwave detector for contactless monitoring
of material flows for “flow” or “no flow”
- Absolutely insensitive against material deposits
- For any line diameter
- With adapter, usable up to 220 °C and 20 bar
- With ceramic mounting, usable up to 1,000 °C
- Usable in dust ex-zones
- Detection through all non-conductive walls
- Can also be supplied as compact device with integrated electronics
- Detection of material clogging and material standstill
What do you want to do?
Use / Function
The FlowJam S detects solid flows of all types for material movement.
A differentiation is made between the following switching states:
- Material flow
- Material clogging / standstill or empty pipe
The system operates with no contact, using microwaves in a process in which the material movement is detected by using the Doppler effect. The FlowJam S is an especially process-secure device, since the microwave can penetrate material coating on the sensor and reliably detect the material movement behind it.
If container walls, housings or pipelines are not metal, it is possible to measure from the outside. The FlowJam S can also be used under difficult conditions such as high operating temperatures and pressures as well as dust and gas ex-zones with the help of a process adapter.
Mounting and Installation
The FlowJam S can be easily installed in the following ways:
- Screwing into a 1 ½-inch-threaded connection
- using a DN 40 flange as well as
- using a pipe clamp or other holding bracket
options are German, English or French.
Technical Data
Sensor | Voltage | 12 V DC – powered by transmitter |
---|---|---|
Power consumption | approx. 1.5 W | |
Housing | Stainless steel 1.4571 | |
Protection system | IP 65 | |
Using in EX-zones | Dust EX-zone 22 Dust EX-zone 20/22 (with process-adapter) |
|
Process temperature | -20 … +80 °C (standard) -20 … +220 °C (with process-adapter) -20 … +1000 °C (with ceramic-flange) |
|
Ambient temperature | -20 … +60 °C | |
Working pressure | max. 1 bar (standard) max. 20 bar (with process-adapter) |
|
Detection range | 0 … 2 m (dependent on application) | |
Required material speed for detection | min. 0.1 m/s | |
Measuring frequency | K-Band 24,125 GHz (± 100 MHz) | |
Transmitting power | max. 5 mW | |
Dimensions | Housing: 103 mm / Ø 52 mm Thread: L 30 mm / Ø G 1 ½” |
|
Weight | approx. 560 g | |
Transmitter | Power supply | 24 V DC ± 10 % |
Power consumption | approx. 3.5 W | |
Relay (max.) – Voltage – Current – Capacity |
110 V AC 1 A 60 W |
|
Fall-delay time | 1… 15 s (continuously adjustable) | |
Weight | approx. 172 g |
Application Examples
Click on a desired application example to navigate to a detailed description.
Plastic granulate
in free falling behind rotary valve
Active carbon exhaust –
air treatment in heat exchanger
Carbon dust feed of primary firing in rotary kiln
Global Technology Systems
P.O. Box 799 Shalimar, FL 32579. USA
(850) 651-3388