850-651-3388

PicoFlow –
Continuous flow measurement
at low solid/air ratios

Measuring powder flows in transport lines with very low material concentrations.

  • In pneumatic applications for material flow rates of up to 100 kg/h
    (depending on application)
  • In free-fall with a drop speed of at least 2 m/s (approx. 25 cm drop height)
  • In cases where dust measuring instruments cannot cope and flow rate
    measuring instruments are overspecified

What do you want to do?

Use

PicoFlow was specially developed for measuring powder flows in transport lineswith very low material concentrations.

PicoFlow is particularly good in pneumatic applications but will also work reliably in free-fall applications with drop speeds of at least 2 m/s.

The measuring system delivers absolute measurements (after calibration)
in g/h or kg/h.

special air purging system is also available as an option.
This is used for materials which tend to bake onto surfaces.

Function

The measuring principle of the PicoFlow is based on the electrodynamic measuring effect.
A ceramic coating on the very short antenna prevents sensor wear.
Specially developed hardware and software allows the measurements to be linearised.

Mounting and Installation

The PicoFlow can be installed in metallic ducts and pipelines.

It should be installed as far as possible away from curves and other fittings such as valves and slides.The distance between the sensor rod and fittings in the duct should be at least three times the duct diameter in every flow direction.

Non-metallic ducts must be cased with a metal sleeve, a metal foil or a tight-mesh metal grille over a length of at least five times the duct diameter.
After deciding the installation location, drill a hole in the duct wall where the supplied weld-on socket can be welded perpendicular to the pipe. Then screw the sensor rod into the socket using the screw-in thread.

Technical Data
Sensor Measurement range From 100 g/h to 100 kg/h (depends on application)
Process temperature Standard: 150 °C; Optional: max. 500 °C
Pressure Max. 2 bar (Optional: up to 25 bar)
Flow velocity Min. 2 m/sec
Humidity 60 % RH or less (non-condensing)
Measurement principle Electrodynamics
Ambient temperature -20 … +60 °C
Sensor rod Material: Stainless steel, AL2O3 ceramic 99,7 %; Length: depends on application
Housing material Aluminium
Protection type IP 66; ATEX: Cat. 1/2 GD
Electrial connection Connection chamber DIN M 20
Switch output measurement alarm Relay with switchover contact – max. 250 V/AC, 1A
Not on EX devices Cat. 1 and 2
Weight Ca. 1.5 kg
Transmitter (field housing) Power supply 110/230 V, 50 Hz (optional 24 V DC)
Power consumption 20 W / 24 VA
Protection type IP 65 to EN 60 529/10.91
Ambient temperature -10 … + 45 °C
Dimensions 258 x 237 x 174 (W x H x D)
Weight approx. 2.5 kg
Interface RS 485 / RS 232 C (ModBus)
Cable screw connectors 3 x M 16 (4.5 – 10 mm Ø)
Connection terminals cable cross-section 0.2 – 2.5 mm² [AWG 24-14]
Current output 4 … 20 mA (0 … 20 mA), load < 500 Ω
Switch output measurement alarm Relay with switchover contact – max. 250 V AC, 1 A
Data backup Flash memory
Pulse output Open collector – max. 30 V, 20 mA
Transmitter (DIN rail) Power supply 24 V DC ± 10 %
Power consumption 20 W / 24 VA
Protection type IP 40 to EN 60 529
Ambient temperature -10 … +45 °C
Dimensions 23 x 90 x 118 (W x H x D)
Weight Approx. 172 g
Connection terminals cable cross-section 0.2 – 2.5 mm² [AWG 24-14]
Current output 4 … 20 mA (0 … 20 mA), load < 500 Ω
Switch output measurement alarm Relay with switchover contact – max. 250 V AC, 1 A
Data backup Flash memory
Pulse output Open collector – max. 30 V, 20 mA