FlowJam Plus – Material flow monitor
with blockage detector
The FlowJam Plus is a logical development of the established FlowJam sensor which has proved its worth in thousands of applications:
- rapid detection of material movement (Flow/NoFlow)
- additional function “Detection of blockage” or “Material flow interruption”
- operates without contact using microwaves
- a particularly reliable device since microwaves can pass through material accumulations
- measurement can be taken from outside all non-metallic tank walls, housings, hose lines or pipelines
- can be used even in difficult conditions, in other words high operating temperatures and pressures and in version for Atex zones (with the help of a processadapter)
What do you want to do?
Function
The FlowJam Plus sends microwaves into the pipeline in which the material flows. This may be a freefall pipeline or a pneumatic transport system.
The microwave signals are reflected by the moving solid particles. A shift in the Doppler frequency between the emitted and received signals means that the material is moving, in other words “Flow”. If this Doppler shift does not take place, there is no material movement and the sensor indicates “NoFlow”.
If this state occurs, the FlowJam Plus can detect on the basis of clear characteristic values from the reflection signal whether a blockage has formed from below or the material supply has been interrupted from above. This switching condition is output by a second relay.
Application Examples
• Transfer point
Chips of wood are transported by two screw conveyors in a biomass plant.
At the transfer point between the screw conveyors, the FlowJam Plus monitors the flow of material.
In the case of a material flow interruption, it is now possible to detect quickly whether there is a problem because the lower screw no longer removes any material or the feed screw no longer supplies material.
• Material infeed to a rotary feeder
In a lime plant, lime is conveyed into the inlet of a rotary feeder via a vertical downpipe. At this point, it should be ensured that there is always a sufficient material flow. When the material column reaches the sensor position in the fall line, the FlowJam Plus signals exactly this state. With this information, the material feed can be controlled better.
Mounting and Installation
Installation
The FlowJam Plus sensor is installed on the line using a G 1½-inch threaded port.
System
A complete measuring point consists of the following components:
• FlowJamPlus sensor
• DIN rail connector
Technical Data
Sensor | Housing material | Stainless steel 1.4571 |
---|---|---|
Protection type | IP 65 | |
Process temperature | – 20 … + 80 °C – 20 … + 220 °C (with process adapter) up to 1000 °C (with ceramic flange) |
|
Ambient temperature | – 20 … + 60 °C | |
Operating pressure | max. 1 bar / Max. 20 bar (with process adapter) | |
Power supply | 18 … 24 V DC / AC | |
Operating frequency | 24.125 GHz; ± 100 MHz | |
Transmission power | max. 5 mW | |
Weight | 1,0 kg | |
Dimensions | Housing: Length 216 mm / Diameter 52 mm Thread: Length 30 mm / Diameter G 1 ½” |
|
Transmitter (DIN rail) | Power supply | 18 … 24 V DC |
2 x relay output – Voltage – Current – Consumption |
Max. 250 V AC Max. 1 A Max. 60 W |
|
Communication | USB | |
Response Time | 1 … 15 s (infinitely variable) | |
Weight | Approx. 172 g |
Global Technology Systems
P.O. Box 799 Shalimar, FL 32579. USA
(850) 651-3388
[email protected]